Controls and Meters - Flow Control Specialists
HOME       ABOUT US       NEWS      CONTACT US       SITE MAP      
 
Flow Measurement
and Control Products
 
Hardware and
Software Integration
 
Control Panel Design
Assembly & Documentation
 
On-Site & In-House
Repair and Proving
 
Case Studies

Water Specialties

Propeller Meters

PROPELLER METERS
Flanged Tube
Top Plate Assemblies
Saddle

TRANSMITTERS

 

 
ML03 Downloads
ML03 Propeller Meter
MODEL ML03 FLANGED TUBE METERS are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The flanged end tube design permits use in a wide range of applications with up to 150 psi working pressure. Flanged ends are 150 lb. AWWA class D flat face steel flanges. Fabricated steel meter tubes have straightening vanes and are protected internally and externally with 12-15 mils of NSF approved, fusion bonded epoxy resin.

ML04Downloads
ML04 Propeller Meter
MODEL ML04 FLANGED TUBE METERS are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The flanged end tube design permits use in a wide range of applications with up to 150 psi working pressure. Flanged ends are 150 lb. AWWA class D flat face steel flanges. Fabricated steel meter tubes have straightening vanes and are protected internally and externally with 12-15 mils of NSF approved fusion epoxy resin.

ML-I1Downloads
MLI1 Meter Head Assy
MODEL MLI1 METER HEAD ASSEMBLIES are manufactured to the
highest standards. Materials used on all meters and flow ranges
for the low velocity meter meet or exceed AWWA standard C704-
02. The bolt-on design permits use in a wide range of applications
with up to 150 psi working pressure. It is necessary, upon ordering,
to furnish the meter size, model number and serial number of the
meter it is replacing.

ML-I1XDownloads
MLI1X Meter Head Assy
MODEL MLI1X METER HEAD ASSEMBLIES are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The bolt-on design permits use in a wide range of existing applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the I.D. dimension of the pipe the meter is to be mounted on for calibration purposes, and the saddle dimensions from the back of the data sheet. It may be necessary to modify or remove the existing straightening vanes
to allow proper clearance for Water Specialties three bladed propeller (see propeller dimension on back of data sheet).

ML-T1Downloads
MLT1 Meter Head Assy
MODEL MLT1 METER HEAD ASSEMBLIES are manufactured to the
highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The bolt-on design permits use in a wide range of existing applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the meter size, model number and serial number of the meter it is replacing.

ML-T1XDownloads
MLT1X Meter Head Assy
MODEL MLT1X METER HEAD ASSEMBLIES are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The bolt-on design permits use in a wide range of existing applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the I.D. dimension of the pipe the meter is to be mounted on for calibration purposes, and the saddle dimensions from the back of the data sheet. It may be necessary to modify or remove the existing straightening vanes to allow proper clearance for Water Specialties three bladed propeller (see propeller dimension on back of data sheet).

LP-21Downloads
LP21 Saddle Meter
MODEL LP21 STRAP-ON SADDLE METERS are designed for irrigation or other low pressure service up to 150 PSI working pressure. The strapon design permits installation on many types of pipe material (3/16" PVC wall minimum). It is necessary upon ordering to furnish the I.D. dimension of the pipe the meter is to be mounted on, for calibration purposes. The pipe O.D. dimension must be 4.50" for proper sealing of the saddle to the pipe.

LP-22Downloads
LP22 Saddle Meter
MODEL LP22 STRAP-ON SADDLE METERS are designed for irrigation or other low pressure service up to 150 PSI working pressure. The strapon design permits installation on many types of pipe material (3/16" PVC wall minimum). It is necessary upon ordering to furnish the I.D. dimension of the pipe the meter is to be mounted on, for calibration purposes. The pipe O.D. dimension must be 4.50" for proper sealing of the saddle to the pipe.

LP-31Downloads
LP31 Saddle Meter
MODEL LP31 STRAP-ON SADDLE METERS are designed for irrigation or other low pressure service up to 150 PSI working pressure. The stainless steel saddle (brass 4") and u-straps permit installation on a wide range of steel, cast-iron, plastic (3/16" PVC wall minimum), asbestos, and other pipe materials for each nominal meter size. It is necessary upon ordering to furnish the I.D. dimension of the pipe the meter is to mounted on, for calibration purposes. The pipe O.D. dimension (20" max.) or wall thickness must also be furnished for proper sizing of the U-straps. NOTE: Consult factory for O.D. larger than 20".

LP-32Downloads
LP32 Saddle Meter
MODEL LP32 STRAP-ON SADDLE METERS are designed for irrigation or other low pressure service up to 150 PSI working pressure. The stainless steel saddle and u-straps permit installation on a wide range of steel, cast-iron, plastic (3/16" PVC wall minimum), asbestos, and other pipe materials for each nominal meter size. It is necessary upon ordering to furnish the I.D. dimension of the pipe the meter is to mounted on, for calibration purposes. The pipe O.D. dimension (20" max.) or wall thickness must also be furnished for proper sizing of the U-straps. NOTE: Consult factory for O.D. larger than 20".

TR01-1Downloads
TR01-1 Transmiitter
MODEL TR01-1 TOTALIZER-TRANSMITTERS provide a totalization of flow volume and a pulse rate output signal proportional to the rate of flow when mounted on our meters. The unit features a magnetically driven totalizer, and solid state construction.

TR06-1Downloads
TR06-1 Transmitter
MODEL TR06-1 INDICATOR-TOTALIZER-TRANSMITTERS provide an instantaneous flow rate indication, a totalization of flow volume and a pulse rate output signal proportional to the rate of flow when mounted on our propeller meters. The unit features a mechanically driven indicator- totalizer, and solid state construction.
 

TR12-2Downloads
TR12-2 Transmitter
MODEL TR12-2 INDICATOR-TOTALIZER-TRANSMITTERS provide an instantaneous flow rate indication, a totalization of flow volume and a pulse rate output signal of one contact per totalizer hand revolution when mounted on any of our propeller meters. The unit features a durable magnetically actuated reed switch.

TR15Downloads
TR15 Transmitter
MODEL TR15 TOTALIZER-TRANSMITTERS provide a totalization of flow volume and both a 4-20 mA current signal and a pulse rate output signal proportional to the rate of flow when mounted on our meters. The unit features a magnetically driven totalizer, and solid state construction.

TR16Downloads
TR16 Transmitter
MODEL TR16 INDICATOR-TOTALIZER-TRANSMITTERS provide an instantaneous flow rate indication, a totalization of flow volume and both a 4-20 mA current signal and a pulse rate output signal proportional to the rate of flow when mounted on our propeller meters. The unit features a mechanically driven indicator-totalizer, and solid state construction.