Water Specialties & Propeller Meters

Propeller Meters

flanged tube meterML03

MODEL ML03 flanged tube meters are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The flanged end tube design permits use in a wide range of applications with up to 150 psi working pressure. Flanged ends are 150 lb. AWWA class D flat face steel flanges. Fabricated steel meter tubes have straightening vanes and are protected internally and externally with 12-15 mils of NSF approved, fusion bonded epoxy resin.

Downloads: brochure | manual


flanged tube meterML04

MODEL ML04 FLANGED TUBE METERS are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The flanged end tube design permits use in a wide range of applications with up to 150 psi working pressure. Flanged ends are 150 lb. AWWA class D flat face steel flanges. Fabricated steel meter tubes have straightening vanes and are protected internally and externally with 12-15 mils of NSF approved fusion epoxy resin.

Downloads: brochure | manual


mli1 head assemblyML-I1

MODEL MLI1 METER HEAD ASSEMBLIES are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The bolt-on design permits use in a wide range of applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the meter size, model number and serial number of the meter it is replacing.

Downloads: brochure | manual


meter head assemblyML-I1X

MODEL MLI1X METER HEAD ASSEMBLIES are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The bolt-on design permits use in a wide range of existing applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the I.D. dimension of the pipe the meter is to be mounted on for calibration purposes, and the saddle dimensions from the back of the data sheet. It may be necessary to modify or remove the existing straightening vanes to allow proper clearance for Water Specialties three bladed propeller (see propeller dimension on back of data sheet).

Downloads: brochure | manual


meter head assemblyML-T1

MODEL MLT1 METER HEAD ASSEMBLIES are manufactured to the
highest standards. Materials used on all meters and flow ranges for
the low velocity meter meet or exceed AWWA standard C704-02. The
bolt-on design permits use in a wide range of existing applications
with up to 150 psi working pressure. It is necessary, upon ordering, to
furnish the meter size, model number and serial number of the meter
it is replacing.

Downloads: brochure


head assemblyML-T1X

MODEL MLT1X METER HEAD ASSEMBLIES are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The bolt-on design permits use in a wide range of existing applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the I.D. dimension of the pipe the meter is to be mounted on for calibration purposes, and the saddle dimensions from the back of the data sheet. It may be necessary to modify or remove the existing straightening vanes to allow proper clearance for Water Specialties three bladed propeller (see propeller dimension on back of data sheet).

Downloads: brochure | manual


head assemblyLP-21

MODEL MLT1X METER HEAD ASSEMBLIES are manufactured to the highest standards. Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The bolt-on design permits use in a wide range of existing applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the I.D. dimension of the pipe the meter is to be mounted on for calibration purposes, and the saddle dimensions from the back of the data sheet. It may be necessary to modify or remove the existing straightening vanes to allow proper clearance for Water Specialties three bladed propeller (see propeller dimension on back of data sheet).

Downloads: brochure | manual


saddle meterML19, ML20, ML20D

MODEL ML19, ML20, ML20D WELD-ON SADDLE METERS Materials used on all meters and flow ranges for the low velocity meter meet or exceed AWWA standard C704-02. The weld-on design permits use in a wide range of applications with up to 150 psi working pressure. It is necessary, upon ordering, to furnish the I.D. dimension of the pipe the meter is to be mounted on for calibration purposes. The O.D. dimension or wall thickness must also be furnished for proper fit of the saddle to the pipe.

Downloads: brochure | manual


lp22 saddle meterLP-22

MODEL LP22 STRAP-ON SADDLE METERS are designed for irrigation or other low pressure service up to 150 PSI working pressure. The strapon design permits installation on many types of pipe material (3/16″ PVC wall minimum). It is necessary upon ordering to furnish the I.D. dimension of the pipe the meter is to be mounted on, for calibration purposes. The pipe O.D. dimension must be 4.50″ for proper sealing of the saddle to the pipe.

Downloads: brochure | manual


saddle meterLP-31

MODEL LP31 STRAP-ON SADDLE METERS are designed for irrigation or other low pressure service up to 150 PSI working pressure. The stainless steel saddle (brass 4″) and u-straps permit installation on a wide range of steel, cast-iron, plastic (3/16″ PVC wall minimum), asbestos, and other pipe materials for each nominal meter size. It is necessary upon ordering to furnish the I.D. dimension of the pipe the meter is to mounted on, for calibration purposes. The pipe O.D. dimension (20″ max.) or wall thickness must also be furnished for proper sizing of the U-straps. NOTE: Consult factory for O.D. larger than 20″.

Downloads: brochure | manual


saddle meterLP-32

MODEL LP32 STRAP-ON SADDLE METERS are designed for irrigation or other low pressure service up to 150 PSI working pressure. The stainless steel saddle and u-straps permit installation on a wide range of steel, cast-iron, plastic (3/16″ PVC wall minimum), asbestos, and other pipe materials for each nominal meter size. It is necessary upon ordering to furnish the I.D. dimension of the pipe the meter is to mounted on, for calibration purposes. The pipe O.D. dimension (20″ max.) or wall thickness must also be furnished for proper sizing of the U-straps. NOTE: Consult factory for O.D. larger than 20″.

Downloads: brochure | manual


vertical upflow meterVF27

MODEL VF27 VERTICAL UPFLOW METERS are designed to meet AWWA specifications. The bolt-on design permits use in a wide range of applications with up to 150 psi working pressure. The mounting flange conforms to ANSI class 125 drilling. It is necessary, upon ordering, to furnish the I.D. dimension of the pipe the meter is to be mounted on for calibration purposes.

Downloads: brochure | manual


totalizer transmitterTR01-1

MODEL TR01-1 TOTALIZER-TRANSMITTERS provide a totalization of flow volume and a pulse rate output signal proportional to the rate of flow when mounted on our meters. The unit features a magnetically driven totalizer, and solid state construction.

Downloads: brochure | manual


totalizer transmitterTR06-1

MODEL TR06-1 INDICATOR-TOTALIZER-TRANSMITTERS provide an instantaneous flow rate indication, a totalization of flow volume and a pulse rate output signal proportional to the rate of flow when mounted on our propeller meters. The unit features a mechanically driven indicator-totalizer, and solid state construction.

Downloads: brochure


totalizer transmitterTR12-2

MODEL TR12-2 INDICATOR-TOTALIZER-TRANSMITTERS provide an instantaneous flow rate indication, a totalization of flow volume and a pulse rate output signal of one contact per totalizer hand revolution when mounted on any of our propeller meters. The unit features a durable magnetically actuated reed switch.

Downloads: brochure | manual


totalizer transmitterTR15

MODEL TR15 TOTALIZER-TRANSMITTERS provide a totalization of flow volume and both a 4-20 mA current signal and a pulse rate output signal proportional to the rate of flow when mounted on our meters. The unit features a magnetically driven totalizer, and solid state construction.

Downloads: brochure | manual


totalizer transmitterTR16

MODEL TR16 INDICATOR-TOTALIZER-TRANSMITTERS provide an instantaneous
flow rate indication, a totalization of flow volume and both a 4-20 mA current signal and a pulse rate output signal proportional to the rate of flow when mounted on our propeller meters. The unit features a mechanically driven indicator-totalizer, and solid state construction.

Downloads: brochure | manual